Record water samples and check results against limits

Set a limit for each parameter, record every sample taken at a reservoir or distribution zone, and enter the laboratory results, which are marked compliant, non-compliant or not evaluated as you save them.

Updated on

Each sampling is stored as a sample, and every laboratory value is compared with the parameter's limit the moment you save it. The Owner, Administrator and Operations roles record samples, results and limits; Field supervisor, Analyst and Viewer can open the pages but cannot change them.

Before you start#

  • The sampling point must exist under Network: a metering zone for samples taken in distribution, or an asset of the reservoir type.
  • Agree a unique code per sample with the laboratory (for example AM-2026-001). A utility cannot hold two samples with the same code.
  • Your role needs write access to monitoring.

Step 1: Set the quality limits#

  1. In the menu, open Water quality and choose Quality limits.
  2. The table lists the five tracked parameters: Residual chlorine, pH, Turbidity, E. coli and Total coliforms. On the parameter's row, click Set (or Edit if it already has a limit).
  3. Check the Unit and fill in the Minimum, the Maximum or both.
  4. Under Source, say where the value comes from: an internal target, a standard, a contract or a regulation.
  5. Click Save. The new limit applies to results entered from then on; earlier results keep the assessment they were given.

Step 2: Record the sampling#

  1. In Samples, click New sample.
  2. Enter the Code, then under Sampled pick Distribution zone or Reservoir and select the Zone or the reservoir.
  3. Enter the Sampling date and time and, optionally, Collected by, Laboratory and Notes.
  4. Click Save. The sample's page opens with the status Collected.

Step 3: Enter the laboratory results#

  1. On the sample's page, click Record result.
  2. Choose the Parameter. Below it you see the limit in force, or a note that none is set.
  3. Enter the Value, check the Unit and, if you like, the Method. Click Save.
  4. Repeat for each parameter the laboratory tested. A sample takes one result per parameter.

What happens next#

  • The sample moves to Analyzed with its first result.
  • Each result shows the Limit applied and its Compliance: Compliant, Non-compliant or Not evaluated (when the parameter has no limit). The sample's page counts the Non-compliant results.
  • Every value is listed under Test results, where you can filter by compliance and export to CSV.
  • If Monitoring holds an active alarm rule that watches Water quality for that parameter, a value past the rule's limit opens an alarm and sends a text message to the rule's Phones to notify. If that rule already has an open alarm for the same sampling point, the new value updates it instead of opening a second one.

Common problems#

  • "This parameter already has a result for this sample." That parameter was already entered. Open the sample and check the value under Results; for a fresh analysis, record a new sample.
  • Save does nothing on a new sample. The code, the date or the zone or reservoir is missing. If the list is empty, the form offers Create a zone or Register an asset: add the point under Network first.
  • "The minimum cannot be greater than the maximum." Swap the values. You must give at least one of the two.
  • A result came out Not evaluated. The parameter had no limit when the value was entered. Set one under Quality limits and later results are assessed against it.