Development build — sample configuration

Network and field work

Know where your pipes and valves are, how much water each part of the network loses, which crew is on which job, whether the water is within its limits and what material is in store. A burst, a failed sample or a shortage of parts reaches the people who have to act on it straight away.

Map of the network

Before a main is shut, the team already knows which valves to close and which customers will lose supply.

  • Shut-off planNames the valves to close, the points left without supply and the customers affected, and warns when valves alone cannot isolate the main.
  • Follow the waterFrom any point in the network, shows everything upstream and downstream of it.
  • Lists to downloadNetwork points and pipe sections download ready to open in a spreadsheet.

Water lost

You see how much water each network zone loses, not just the total for the system.

  • Night-time burst signsFlow between 2 and 4 in the morning is compared with earlier nights, and nights well above normal are marked as a possible burst.
  • Apparent and real lossesEnter the share you assume for apparent losses and the losses are split; without that figure, no split is made.
  • Closed periodsA finished, complete period can be recorded and then stays fixed; different figures are kept as a revision.

Work orders

Every crew leaves with the right job, the right skills and its materials set aside.

  • The crew with the right skillAn order goes only to a crew with the skill it needs; automatic assignment picks the available crew with the least work waiting.
  • Materials before leavingIf the required materials are not set aside, the order is not sent out, and the message says what is missing.
  • Proof of disconnectionA disconnection for debt closes only with the seal number and a photo; a No access result needs notes.

Water quality

A result outside its limit reaches the phone of whoever is on duty at once.

  • Alarm by text messageA rule above or below a value opens an alarm when a result crosses it and sends a text message to the duty phones.
  • No repeated alarmsAn alarm clears only when the value crosses a second threshold, so a reading hovering at the limit does not keep opening and closing it.
  • A faithful recordEach result keeps the limit in force when it was entered, and changing a limit never alters past results.

Stock and materials

Parts are in the store or on the van when the crew needs them.

  • Shortage alertsNegative balances, items at or below their reorder level and stock that falls short of planned orders appear in one list.
  • Stock counts approved twiceDifferences found in a count become adjustments only when a second person, with supervisor rights, approves them.
  • Meters by serial numberEach meter keeps its own history: in stock, installed, in testing, written off or lost.

Start today. Set up your utility in minutes.